VAMFC & VAM-J heat reclaim ventilation (HRV) units 19 VH- electrical heaters for VAM units 20 VKM-GB/GBM HRV units with DX coil 20 ALB-R/LBS - HRV units with premium efficiency 21 All Daikin VRV units have the inverter technology. The principle is simple: inverters adjust the power used to suit the actual requirement - Malfunctionof transmission (between heat reclaim ventilation unit and fan unit) Defect of fan unit PCB. Defect of connecting wire between (1) and (2) 95: System No. 1. Malfunction of inverter system: Defect of fan inverter unit 96: System No. 2. Malfunction of inverter system: Defect of fan inverter unit 97: Malfunction of thermal storage unit Toachieve optimal ventilation, Daikin maintains the highest standards of energy efficiency and flexibility to deliver the best indoor air quality. To attain clean indoor air, Daikin ensures its ventilation products are seamlessly integrated in a total heat pump solution. This means we reduce the number of individual systems and independent suppliers to deliver one complete HVAC system. Гаматана Daikin за запазване на топлината при вентилация подобрява енергийната ефективност и осигурява Installationmanual EVLQ05+08CAV3 Daikin Altherma hybrid heat pump - outdoor unit 4P - 2013.02 Page 7: Starting Up The Outdoor Unit Install the Installation and operation manual Heat reclaim ventilation unit VAM350J7VEB VAM500J7VEB VAM650J7VEB VAM800J7VEB VAM1000J7VEB Daikin Europe N.V. is TotalHeat Exchanger HRV (Heat Reclaim Ventilation) Operation manual HRV - Heat Reclaim Ventilation Before using the DAIKIN HRV, be sure to read this operation manual thoroughly. If you have any problems or there is a malfunction, please refer to this operation manual. Please keep this manual for your future reference . VAM-HVE VAM-HVE Heat Reclaim Ventilator Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP* of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. *Max ESP varies from 130 Pa to 235 Pa depending on the model class Download Brochure All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Technical Specifications Available Options System Reverse Cycle Capacities Indoor Type Heat Reclaim Ventilator Power Supply Refrigerant VAM-HVE Flyer Our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range. Furthermore, improved external static pressures offer greater design flexibility to support variety of duct layouts. Send the brochure to me. Enter your email below to receive the brochure link in your inbox Air Treatment Equipment CEK HARGA=> KATALOGUE=> SPESIFIKASI=> Heat Reclaim Ventilator — VAM series Model Names VAM150GJVE, VAM250GJVE, VAM350GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVE Improved Enthalpy Efficiency*1 Higher External Static Pressure*2 Enhanced Energy Saving Functions Seri VAM ini memberikan efisiensi entalpi yang lebih tinggi*1, karena kinerja elemen film tipis yang sangat ditingkatkan. Selain itu, tekanan statis eksternal yang ditingkatkan*2 menawarkan lebih banyak fleksibilitas untuk pemasangan. Seiring dengan ketiga peningkatan luar biasa ini, operasi pendinginan malam hari gratis berkontribusi pada konservasi energi dan lingkungan yang lebih nyaman. Product Highlights Product Range Capacities View AR View 360 DX coil cooling capacity Airflow rate 500-950 m3 /h Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. Equipped with a heat reclaim ventilator and a heat exchanger DX coil, VKM series is capable of minimizing room temperature fluctuations. VKM series maintains comfortable indoor air quality IAQ by adding fresh outdoor air having nearly the same temperature and humidity conditions as the indoor air. Thus, VKM ensures optimum comfort and further reduces air conditioning load. VKM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VKM Supply Air duct. Heat Reclaim Ventilator + Heat Exchanger → Comfortable Air Supply Equipped with a heat reclaim ventilator and a heat exchanger, the new VKM series minimizes room temperature fluctuations. A Compact Unit Packed with Daikin’s Cutting-Edge Technologies. Air Conditioning and Outdoor Air Processing Can be Accomplished Using a Single System. When the VKM series units are connected, the total connection capacity index must be 50% to 130% of the capacity index of the outdoor units. Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. Tech specs Specifications ModelVKM50GCVEVKM80GCVEVKM100GCVE Power Consumption Heat Exchange modeW 270/230/170390/335/220440/370/260 Power Consumption Bypass modeW305/260/200390/335/220440/370/260 External static Pressure Pa210/170/140220/180/125170/120/90 Airflow rate m3/h500/500/440750/750/640950/950/820 Sound level Heat Exchange modedB43/ Sound level Bypass modedB43/41/ Temp exchange efficiency %76/76/ Enthalpy exchange efficiency %64/64/6766/66/6862/62/66 DX-coil Capacity kW Dimensions H x W x D387x1764x832387x1764x1214387x1764x1214 Machine weight kg92113115 You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE

daikin heat reclaim ventilator